栏目导航
navigation
日本CCS电源PD3-5024-4-SI(A)
发布时间:2024-04-28
日本CCS电源PD3-5024-4-SI(A)
日本CCS电源PD3-5024-4-SI(A)
Standard Product
This Digital Control Unit can be used for LED Light Units with an input voltage of 24 V within a total power consumption of 46 W.
Connection with the HLV3/HLV2-series Spot Lights is also available.
This Control Unit operates on a 100 to 240 VAC input and measures 197 x 82.6 x 120 mm (width x depth x height). External control through EIA-485 communications.
Product Details
Dimensions | W 197 mm x D 82.6 mm x H 120 mm |
---|---|
Applicable Light Unit (output ratings) | Light Units with 24 VDC input, HLV3/HLV2 series (Spot Light) Total for 4 channels: 46 W |
Number of channels | 4 channels |
Lighting method | Constant/Strobe lighting |
Drive method | 24V LIGHT connectors: Constant-voltage system, HLV LIGHT connectors: Constant-current system |
Intensity control method | 24V LIGHT connectors: PWM control and lighting time control, HLV LIGHT connectors: Variable-current control |
PWM frequency | 125kHz |
Input voltage | 100 to 240 VAC (+10% -15%) |
Frequency | 50/60 Hz |
Power consumption | 70 VA |
Output voltage | 24VDC |
Output current | Total for 4 channels: 1.91 A |
Inrush current | 15 A (at 100 VAC), 30 A (at 200 VAC) from a cold start |
Intensity control | Manual: 256-step using the front setting switch External: Command input via EIA-485 communication |
Error detection display | Digital display on the front-panel; OCP: Overcurrent error, EFN: Fan Stop Error, and EID: ID error (HLV3/HLV2-series Spot Lights only) |
Error detection output | Command sent when overcurrent output is detected. |
Over current protection | Operates at 107% of rated output current or higher. Reset by pressing operation setting switch for at least 1 second or by cycling the power supply. *Do not intentionally short-circuit the positive and negative output terminals. |
Output connector | SMP-03V-BC x 8 |
External control connector | Trigger input: MIL connector (MIL-C-83503 compliant), 10 pins For setting the light intensity/mode: e-CON connector, 3 pins |
Conformed standards | CE, UKCA、RoHS |
Operating temperature and humidity | Temperature: 0 to 40°C, Humidity: 20 to 85%RH (no condensation) |
Storage temperature and humidity | Temperature: -20 to 60°C, Humidity: 20 to 85%RH (no condensation) |
Cooling method | Forced cooling |
Weight | 1,200 g |
Material | Aluminium, ABS |
Accessories | 2m long 3-pin power cord with ground terminal x1 Base Brackets x1 set Instruction Guide x1 |
Program | [Sample Program] Sample programs are available. See the Options tab. |