navigation
日本ORION好利旺CBF组合干泵CBF1515-VB-01B
日本ORION好利旺CBF组合干泵CBF1515-VB-01B
CBF Combination Dry PumpSafety Enhanced Design・Low Noise ・ Long Life ・ Environmentally Friendly
CBF1515 / CBF2525 / CBF4040
Continuous Operating Vacuum
Recomm. 60 kPa or less
(V Type)
Continuous Operating Pressure
Recomm. 60 kPa or less
(B Type)
Continuous Combined Operating Vacuum & Pressure
Total Combined Vacuum & Pressure 60 kPa or less
(VBVB Type)
Flow Rate
280 to 685 L/min (60 Hz)
Safe and Environmentally Conscious
CE Marking CertifiedQuiet Operation
Noise level reduced by 3 dB (compared with conventional models)Long Life
Increased 30% with newly developed vane blade material. (Compared with conventional models).

Specifications
Model CBF1515- | VB-01B | VB-04B ※3 | VBVB-01B | VBVB-04B ※3 | |
---|---|---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 235/280 Pump 2 (V):235/280 | Pump 1 (V,B): 235/280 Pump 2 (V,B):235/280 | ||
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - | ||
Continuous Operating Pressure (B) ※2 | kPa (max.) | 60 | - | ||
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | Recom. ※5, Max. ※6 | ||
Piping Connection Size | Rc 3/4 | ||||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400, 415/ 3-phase 400, 440, 460 | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400、415/ 3-phase 400, 440, 460 |
Standard Motor Current Rating (50/60 Hz) | A | 3.8/ 3.4, 3.4, 3.4 | 2.0, 1.9, 1.9/ 1.7, 1.7, 1.7 | 3.8/ 3.4, 3.4, 3.4 | 2.0, 1.9, 1.9/ 1.7, 1.7, 1.7 |
Noise Level (50/60 Hz) ※4 | dB | 62/63 | 65/66 | ||
Motor | kW | 0.75 | |||
Mass | kg | 37 |
Model CBF1515- | VV-01B | BB-01B | |
---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 235/280 Pump 2 (V):235/280 | Pump 1 (B): 235/280 Pump 2 (B):235/280 |
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - |
Continuous Operating Pressure (B) ※2 | kPa (max.) | - | 60 |
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | |
Piping Connection Size | Rc 3/4 | ||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | |
Standard Motor Current Rating (50/60 Hz) | A | 3.8/3.4, 3.4, 3.4 | |
Noise Level (50/60 Hz) ※4 | dB | 61/62 | 65/66 |
Motor | kW | 0.75 | |
Mass | kg | 37 |
Model CBF2525- | VB-01B | VB-04B ※3 | VBVB-01B | VBVB-04B ※3 | |
---|---|---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 405/480 Pump 2 (V):405/480 | Pump 1 (V,B): 405/480 Pump 2 (V,B):405/480 | ||
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - | ||
Continuous Operating Pressure (B) ※2 | kPa (max.) | 60 | - | ||
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | Recom. ※5, Max. ※6 | ||
Piping Connection Size | Rc 3/4 | ||||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400, 415/ 3-phase 400, 440, 460 | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400、415/ 3-phase 400, 440, 460 |
Standard Motor Current Rating (50/60 Hz) | A | 6.8/ 6.4, 6.0, 6.0 | 3.5, 3.4, 3.4/ 3.2, 3.0, 3.0 | 6.8/ 6.4, 6.0, 6.0 | 3.5, 3.4, 3.4/ 3.2, 3.0, 3.0 |
Noise Level (50/60 Hz) ※4 | dB | 64/67 | 67/70 | ||
Motor | kW | 1.5 | |||
Mass | kg | 52 |
Model CBF2525- | VV-01B | BB-01B | |
---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 405/480 Pump 2 (V):405/480 | Pump 1 (B): 405/480 Pump 2 (B):405/480 |
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - |
Continuous Operating Pressure (B) ※2 | kPa (max.) | - | 60 |
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | |
Piping Connection Size | Rc 3/4 | ||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | |
Standard Motor Current Rating (50/60 Hz) | A | 6.8/6.4, 6.0, 6.0 | |
Noise Level (50/60 Hz) ※4 | dB | 63/66 | 67/70 |
Motor | kW | 1.5 | |
Mass | kg | 52 |
Model CBF4040- | VB-01B | VB-04B ※3 | VBVB-01B | VBVB-04B ※3 | |
---|---|---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 575/685 Pump 2 (V):575/685 | Pump 1(V,B): 575/685 Pump 2 (V,B):575/685 | ||
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - | ||
Continuous Operating Pressure (B) ※2 | kPa (max.) | 60 | - | ||
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | Recom. ※5, Max. ※6 | ||
Piping Connection Size | Rc 3/4 | ||||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400, 415/ 3-phase 400, 440, 460 | 3-phase 200/ 3-phase 200, 220, 230 | 3-phase 380, 400、415/ 3-phase 400, 440, 460 |
Standard Motor Current Rating (50/60 Hz) | A | 10.6/ 9.4, 9.2, 9.2 | 5.3, 5.3, 5.4/ 4.7, 4.6, 4.6 | 10.6/ 9.4、9.2、9.2 | 5.3, 5.3, 5.4/ 4.7, 4.6, 4.6 |
Noise Level (50/60 Hz) ※4 | dB | 68/70 | 69/71 | ||
Motor | kW | 2.2 | |||
Mass | kg | 67 |
Model CBF4040- | VV-01B | BB-01B | |
---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1 (V): 575/685 Pump 2 (V):575/685 | Pump 1 (B): 575/685 Pump 2 (B):575/685 |
Continuous Operating Vacuum (V) ※2 | kPa (max.) | 60 | - |
Continuous Operating Pressure (B) ※2 | kPa (max.) | - | 60 |
Continuous Combined Operating Vaccum & Pressure (VB) | kPa | - | |
Piping Connection Size | Rc 3/4 | ||
Voltage (50/60 Hz) | V | 3-phase 200/ 3-phase 200, 220, 230 | |
Standard Motor Current Rating (50/60 Hz) | A | 10.6/9.4, 9.2, 9.2 | |
Noise Level (50/60 Hz) ※4 | dB | 67/69 | 71/73 |
Motor | kW | 2.2 | |
Mass | kg | 67 |
Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
Operable range of vacuum (pressure).
"04" models are special order items.
Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
Recommended range of combined vacuum and pump pressures: 60 or lower.
Maximum vacuum/pressure per pump can be any combination of the following (vacuum/pressure): 55/20, 55/30, 40/40, 35/50. The maximum vacuum/pressure of the dry pump indicates the maximum sustainable vacuum/pressure. Do not operate the pump beyond this maximum value. Doing so can reduce the lifespan of the pump and may result in breakdown or an accident.
Please consult with your dealer regarding operation in extremely dry environments, as doing so may lead to pump damage.
Allowable intermittent power supply voltage fluctuation range is +10% of the specified voltage, allowable sustained supply voltage fluctuation range is +5% of the specified voltage.
When using other than the ORION standard motor, follow the electrical guidelines printed on the nameplate of the motor used.
Please install an overload protection device (such as a thermal relay).
Scroll